Working frequency

531kHz to 1602 kHz

Power output

Maximum 450W (HCD450/S4), 375W (HCD375/S4), 300W (HCD300/S4), 225W (HCD225/S4) or 150W (HCD150/S4),

+1 - 0 dB into 50 W load with VSWR not exceeding 1.4:1 at the carrier frequency. Remote control of output power available, down to –4dB (40% of maximum rated output)
Power outputs can be doubled with combined pairs

Modulation rating

Rated for continuous 100% sine wave modulation in the range 40 Hz to 10 kHz in ambient temperature 0 to 45ºC. Altitude to 1000 m. Capable of 125% positive modulation

Carrier shift

Not greater than 5% amplitude at 100% modulation

AF response

± 1.5 dB wrt 50% modulation at 1 kHz over the frequency range 40 Hz to 6 kHz. Better than -3 dB at 10 kHz

Distortion-harmonic

Not exceeding 2% THD at modulation levels up to 90% at any modulating frequency in the range 40 Hz to 6 kHz

Intermodulation

With two modulating tones in the range 100 Hz to 5 kHz each modulating the transmitter to 47.5% no intermodulation products exceed -40 dB wrt 100% modulation

Noise level

Amplitude modulated noise in the range 40 Hz to 10 kHz at least 60 dB below 100% modulation

Spurious outputs

When operated into a test load the mean power of any spurious signals will not exceed -60 dB wrt carrier

Harmonics

Harmonics of the carrier frequency will not exceed -50 dB wrt carrier

AF input

600 W balanced. 0 dBm to +10 dBm for 100% modulation

Mains supply

230V +10%, -6%, 50 Hz ± 2 Hz

Power consumption of HCD450/S4 pair at 450W carrier is 700W and with 100% modulation is 1000W

Size

Single Tx case: 9U high, 19" rack mounted

Installed Tx with 3U vent panels top & bottom: 15U high