Model |
HCD760SC |
|
Frequency |
5 & 10MHz, other frequencies
4 to 16MHz to order |
|
Output |
Sine, 0.5V RMS (+7dBm ±1) into
50Ù |
|
Frequency Ageing Rate per
day, at despatch
|
<±1x10-10 |
|
Projected Ageing Rate per year |
<±1.0x10-8 |
|
Operating Temperature Range |
Standard -20 to +70oC,
options down to -40oC possible |
|
Temperature Stability |
<±1x10-9 over
range -20 to +70oC |
|
Stability With Supply Voltage |
<±2.5x10-10 for
5% change from nominal |
|
Stability With Load Change |
<±5x10-10
for 10% change from 50W |
|
Short Term Stability (1 sec) |
<±5x10-12 |
| Phase Noise |
Offset |
Typical values |
| (data for 10MHz
quoted) |
10Hz |
-130dBc/Hz |
|
100Hz |
-140 |
|
1kHz |
-150 |
|
50kHz |
-155 |
|
10kHz |
-155 |
|
Warm-Up Error |
±5x10-9 of final
frequency after 20mins max. at +25oC |
|
Frequency Adjustment,
(electrical only), +0.5 to 7.0V, stabilised output provided |
Sufficient for minimum of 10 years ageing
|
|
±2.5x10-7
approx. Positive slope |
|
Power Supply |
12V DC standard, other options
from 12-30V possible
|
| Power Consumption |
5.5W maximum at switch on
|
|
|
Typically 1.75W when stabilised
at +25oC |
| Harmonics |
<-30dB
wrt carrier |
|
Dimensions (max) |
51mm
long
|
|
41mm wide |
|
30mm high |
|
Shock |
IEC 68-2-27 Test Ea. 50G for
11mS |
|
Vibration |
IEC 68-2-06 Test Fc. 10-55 Hz, 1.5mm
|
|
55-500Hz,
10G |
|
Storage Temperature |
-40 to +90oC |
|
Humidity |
>90% non-condensing, sealed
package |