Model |
HCD331 |
|
Frequency |
13 to 20MHz |
|
Output |
HCMOS, max. 50pF load |
|
Frequency Ageing Rate per
day, at despatch
|
<±3x10-9,
<20MHz <±5x10-9, 20 to 50MHz |
|
Projected Ageing Rate per year |
±3x10-7 |
|
Operating Temperature Range |
Standard -20 to +60oC |
|
Other
options available in range –40oC to +75oC |
|
Temperature Stability |
<±5x10-8 over -20oC
to +60oC |
|
Stability With Supply Voltage |
<5x10-8 for ±5%
change, frequency control voltage constant |
| Phase Noise |
Offset |
Typical values |
| (data for 10MHz
quoted) |
10Hz |
-100dBc/Hz |
|
100Hz |
-120 |
|
1kHz |
-135 |
|
50kHz |
-150 |
|
10kHz |
-150 |
| Duty Cycle |
55:45
maximum. 10-90% rise/fall 5ns |
|
Warm-Up Error |
<±5x10-8 of final
frequency after 10mins at +25oC |
|
Frequency Adjustment,
(electrical only), +0.5 to 4.0V, stabilised output provided |
Typically 5x10-6
total span, sufficient for a minimum of 15 years ageing |
|
Power Supply |
5V DC, ±0.25V maximum
|
|
Power Consumption |
4.5W maximum at switch on |
|
Typically
<1.0W when stabilised at +25oC |
|
Dimensions (max) |
36.1mm long
|
|
27.2mm
wide |
|
15.0mm
high |
|
Option of
13.3mm high case (limited to operating temperature |
|
range –10
to +70oC) |
|
Shock |
IEC 68-2-27 Test Ea. 50G for
11ms |
|
Vibration |
IEC 68-2-06 Test Fc. 10-55 Hz,
1.5mm
|
|
55-500Hz,
10G |
|
Storage Temperature |
-40 to +90oC |
|
Humidity |
>90% non-condensing, sealed
package |